SG580
Conventional explosive gase sensor for tertiary use. IP66
The device has the capacity to control, the presence of various types of gases explosive, toxic. The sensor is managed by a microprocessor which allows execution of a self-diagnosis and therefore an automatic calibration, in order to always have the maximum detection accuracy.
The sensor has a 0 ÷ 20 % L.E.L. linear output, conforming to the 4 ÷ 20mA standard.
The more important news of this sensor is the capability to change the sensing element at the end of the life-cycle directly from a technician without need to send back the sensor for assistance.
Test: to perform a precise and self-certified test, use the TS1008 instrument, which also serves to carry out the annual check.
Primary power supply: 12 ÷ 24 VDC ± 10%
Absorption: 1W max @ 13.8V
Signals: green LED regular function, yellow Fault light, red alarm light
Sensor: Catalytic
Sensor replacement: Autonomously
Operating range selected: 0 ÷ 20% or 0 ÷ 100%
Output signal: 4 ÷ 20 mA on 220 Ohm
Data transmission: Not present
Test socket for: TS1008
Compatible ECUs: The whole Beinat series
Working temperature: 50 ° C
Protection degree: IP66 NO ATEX
Container and Dimensions: 100mm Aluminum
Package Dimensions: 197x122x67
Weight: approx. 250 grams
The perfect partner for the wholesaler
For years, Beinat is your company’s trusted partner: its products are 100% guaranteed and its reliability allows a constant turnover within your warehouse. The study of our products allows obtaining advanced equipment capable to meet all needs. Our quality certifications and warranty
Our quality and guarantee certifications
The importance of quality policy
The goal has always been to provide products that meet the customer’s needs, through continuous performance improvement and with a full commitment.